Caledonian fireflix Cables

CABLE CONSTRUCTION
fireflix cables are constructed in the following typical design:
  1. Solid/stranded annealed copper conductor
   2. Glass mica tape/silicone rubber as flame barrier
  3. XLPE/silicone rubber as insulation
  4. LSZH/Flame retardant RPVC as sheath
fireflix cables are offered in either single core, multicore or multi-pair constructions.
The insulation material can be elastomeric (EPR, SR), thermosetting (XLPE, LSZH) or thermoplastic (EVA, LSZH) to meet different stringent environment requirement. The cables may be armoured or braided, with or without metallic screen, depending on different applications.

INTERNATIONAL STANDARD
The fireflix cables manufactured by Caledonian comply with either one or combination of the following standards.
BS 6387
IEC 60331
IEC 60332-1
IEC 60332-3C
IEC 61034-1/2
IEC 60754-1

 

 

 

PRODUCTS

Fire Resistant offshore & Marine Cables (BS 6883&BS7917)
LV Flame Retardant Power & Control Cables

0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured
Application
These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.
Standards
BS 7917
IEC 60331-31 Fire resistant
IEC 60332-3A Flame retardant
IEC 60754-1; IEC 60754-2 Corrosivity
IEC 61034-2 Smoke density
Cold bend and impact (-40°C) (on request)
CSA C22.2 No. 38-95 (on request)

Construction
Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.
Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.
Mechanical and Thermal Properties
Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)
Temperature Range: -40℃ ~ +90℃

0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured
Download details in PDF

Download details in Word

Caledonian Cables |FAQ |© 2020