Caledonian fireflix Cables


CABLE CONSTRUCTION
fireflix cables are constructed in the following typical design:
  1. Solid/stranded annealed copper conductor
   2. Glass mica tape/silicone rubber as flame barrier
  3. XLPE/silicone rubber as insulation
  4. LSZH/Flame retardant RPVC as sheath
fireflix cables are offered in either single core, multicore or multi-pair constructions.
The insulation material can be elastomeric (EPR, SR), thermosetting (XLPE, LSZH) or thermoplastic (EVA, LSZH) to meet different stringent environment requirement. The cables may be armoured or braided, with or without metallic screen, depending on different applications.

INTERNATIONAL STANDARD
The fireflix cables manufactured by Caledonian comply with either one or combination of the following standards.
BS 6387
IEC 60331
IEC 60332-1
IEC 60332-3C
IEC 61034-1/2
IEC 60754-1

 

 

 

PRODUCTS

Flame Retardant offshore & Marine Cables(IEC 60092)
MariFlex Marine Fire Resistant Power & Control Cables

MFX400 0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed (Multicore)
Application
These unarmoured fire resistant cables are used on board of ships in all locations for fixed installations where cable protection is not required. These cables are fire resistant, flame retardant, low smoke & halogen free.
Standards
IEC 60092-350/351/353/359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1/2
IEC 61034

Construction
Conductors:
Class 2 stranded copper conductor. Class 5 stranded conductors can be offered upon request.
Insulation: Mica tape + XLPE.
Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request.
Core Identification
Two cores: Blue, Brown.
Three cores: Brown, Black, Grey.
Four cores: Blue, Brown, Black, Grey.
Five cores: Blue, Brown, Black, Grey, Black.
Multi cores: White with black numbers.
Mechanical and Thermal Properties
Bending Radius for Fixed Installations: 6×OD (OD>25mm); 4×OD (OD ≤25mm)
Temperature Range: -30℃ ~ +80℃

MFX400 0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed (Multicore)

Download details in PDF

Download details in Word