Caledonian FIREGUARD Cables

CABLE CONSTRUCTION
FIREGUARD cables are constructed in the following typical design:
  1. Solid/stranded annealed copper conductor
   2. Glass mica tape/silicone rubber as flame barrier
  3. XLPE/PVC as insulation
  4. Normal or Flame retardant FRPVC as sheath
FIREGUARD cables are offered in either single core, multicore or multi-pair constructions.
The insulation material is usually PVC with different levels of fire retardance properties to meet different stringent environment requirement. The cables may be armoured or braided, with or without metallic screen, depending on different applications.

INTERNATIONAL STANDARD
The FIREGUARD cables manufactured by Caledonian comply with either one or combination of the following standards.
IEC 60332-1
IEC 60332-3C

 

 

PRODUCTS

Flame Retardant offshore & Marine Cables(IEC 60092)
MariTox Marine Flame Retardant Medium Voltage Cables
MTX 3.6/6kV, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured(Halogen Free Inner Covering
MTX 3.6/6kV, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured (SHF1 Inner Sheath
)
MariTox Marine Flame Retardant Power & Control Cables
MTX300 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed (Single Core)
MTX400 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed (Multicore)
MTX300 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured (Single Core)
MTX400 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured(Multicore)
MTX300 0.6/1 kV HEPR Insulated, LSOH (SHF1) Sheathed(Single Core)
MTX400 0.6/1 kV HEPR Insulated, LSOH (SHF1) Sheathed(Multicore)
MTX300 0.6/1 kV HEPR Insulated, LSOH (SHF1) Sheathed, Screened(Single Core)
MTX400 0.6/1 kV HEPR Insulated, LSOH (SHF1) Sheathed, Screened (Multicore)
MariSig Flame Retardant Instrumentation & Control Cables
MRE-2XH 150/250V XLPE Insulated, LSOH (SHF1) Sheathed (Multicore)
MRE-2XCH 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured(Multicore)
MRE-2XCH 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured (Multipair/Multitriple)
MRE-2X(St)HCH 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened & Armoured (Multipair/Multitriple)
MRE-2X(St)H 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened (Multipair/Multitriple)
MRE-2XH PiMF/TiMF 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Individual Screened(Multipair/Multitriple)
MRE-2XCH PiMF/TiMF 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Individual Screened & Armoured (Multipair/Multitriple)
MRE-3GCH 150/250V HEPR Insulated, LSOH (SHF1) Sheathed, Armoured (Multipair)

Caledonian Cables |FAQ |© 2020